Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Orthop Surg Res ; 19(1): 245, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627743

RESUMO

PURPOSE: The objective of this study was to examine the predictive value of a newly developed MRI-based Endplate Bone Quality (EBQ) in relation to the development of cage subsidence following anterior cervical discectomy and fusion (ACDF). METHODS: Patients undergoing ACDF for degenerative cervical diseases between January 2017 and June 2022 were included. Correlation between EBQ scores and segmental height loss was analyzed using Pearson's correlation. ROC analyses were employed to ascertain the EBQ cut-off values that predict the occurrence of cage subsidence. Multivariate logistic regression analyses were conducted to identify the risk factors associated with postoperative cage subsidence. RESULTS: 23 individuals (14.56%) exhibited the cage subsidence after ACDF. In the nonsubsidence group, the average EBQ and lowest T-score were determined to be 4.13 ± 1.14 and - 0.84 ± 1.38 g/cm2 respectively. In contrast, the subsidence group exhibited a mean EBQ and lowest T-score of 5.38 ± 0.47 (p < 0.001) and - 1.62 ± 1.34 g/cm2 (p = 0.014), respectively. There was a significant positive correlation (r = 0.798**) between EBQ and the segmental height loss. The EBQ threshold of 4.70 yielded optimal sensitivity (73.9%) and specificity (93.3%) with AUC of 0.806. Furthermore, the lowest T-score (p = 0.045, OR 0.667) and an elevated cervical EBQ score (p < 0.001, OR 8.385) were identified as significant risk factors for cage subsidence after ACDF. CONCLUSIONS: The EBQ method presents itself as a promising and efficient tool for surgeons to assess patients at risk of cage subsidence and osteoporosis prior to cervical spine surgery, utilizing readily accessible patient data.


Assuntos
Vértebras Cervicais , Fusão Vertebral , Humanos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Pescoço/cirurgia , Discotomia/efeitos adversos , Discotomia/métodos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Resultado do Tratamento
2.
Spine (Phila Pa 1976) ; 46(4): 209-215, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33156279

RESUMO

STUDY DESIGN: Clinical case series. OBJECTIVE: The aim of this study was to propose a novel posterior ligament-bone injury classification and severity (PLICS) score system that can be used to reflect the severity of subaxial cervical fracture dislocations (SCFDs) and predict the failure of anterior-only surgery; and to measure the intraobserver and interobserver reliability of this system. SUMMARY OF BACKGROUND DATA: The approach selection for SCFDs is controversial. Although the anterior approach is familiar for most surgeons, postoperative hardware failure and/or delayed cervical deformity is a nonnegligible complication. METHODS: Ten patients were randomly selected for intraobserver reliability evaluation on two separate occasions, one month apart. Another 30 patients were randomly selected, and the interobserver reliability was measured by comparing results of each case between each reviewer and averaging. To analyze the difference in the PLICS score, 354 patients fulfilled the follow-up were divided into stable and unstable groups according to whether radiologically stable was observed during follow-up. RESULTS: For the intraobserver reliability, the mean intraclass correlation coefficient for the 10 reviewers was 0.931. For the interobserver reliability, the mean interobserver correlation coefficient for the three elements was 0.863. Among 16 patients with PLICS score ≥7, two patients in the stable group manifested with severe injury of the posterior ligamentous complex (PLC); extremely unstable lateral mass fractures with or without severe injury of PLC were detected in the 14 patients of the unstable group. CONCLUSION: The proposed PLICS score system showed excellent intraobserver and interobserver reliability. When a PLICS score is >7 or 7 accompanied by extremely unstable lateral mass fractures, the risk of postoperative failure after an anterior-only reconstruction is high and supplemental posterior strengthening can be considered.Level of Evidence: 4.


Assuntos
Vértebras Cervicais/lesões , Luxações Articulares/classificação , Ligamentos/lesões , Complicações Pós-Operatórias/classificação , Índice de Gravidade de Doença , Fraturas da Coluna Vertebral/classificação , Articulação Zigapofisária/lesões , Adulto , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Feminino , Seguimentos , Humanos , Escala de Gravidade do Ferimento , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Ligamentos/diagnóstico por imagem , Ligamentos/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Valor Preditivo dos Testes , Distribuição Aleatória , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Falha de Tratamento , Adulto Jovem , Articulação Zigapofisária/diagnóstico por imagem , Articulação Zigapofisária/cirurgia
3.
BMC Cancer ; 20(1): 1026, 2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-33097010

RESUMO

BACKGROUND: Circular RNAs (circRNAs) have emerged as a novel category of non-coding RNA, which exhibit a pivotal effect on regulating gene expression and biological functions, yet how circRNAs function in osteosarcoma (OSA) still demands further investigation. This study aimed at probing into the function of hsa_circ_0000282 in OSA. METHODS: The expressions of circ_0000282 and miR-192 in OSA tissues and cell lines were examined by quantitative real-time polymerase chain reaction (qRT-PCR), and the correlation between the expression level of circ_0000282 and clinicopathological features of OSA patients was analyzed. The expressions of X-linked inhibitor of apoptosis protein (XIAP), B-cell lymphoma-2 (Bcl-2) and Bcl-2 associated X protein (Bax) in OSA cells were assayed by Western blot. The proliferation and apoptosis of OSA cells were examined by CCK-8, BrdU and flow cytometry, respectively. Bioinformatics analysis, dual-luciferase reporter gene assay and RIP experiments were employed to predict and validate the targeting relationships between circ_0000282 and miR-192, and between miR-192 and XIAP, respectively. RESULTS: Circ_0000282 was highly expressed in OSA tissues and cell lines, which represented positive correlation with Enneking stage of OSA patients and negative correlation with tumor differentiation degree. In vitro experiments confirmed that overexpression of circ_0000282 markedly facilitated OSA cell proliferation and repressed cancer cell apoptosis in comparison to control group. Besides, knockdown of circ_0000282 repressed OSA cell proliferation and promoted apoptosis. Additionally, the binding relationships between circ_0000282 and miR-192, and between miR-192 and XIAP were validated. Circ_0000282 indirectly up-regulated XIAP expression by adsorbing miR-192, thereby playing a role in promoting cancer in OSA. CONCLUSION: Circ_0000282 was a novel oncogenic circRNA in OSA. Circ_0000282/miR-192/XIAP axis regulated OSA cell proliferation apoptosis with competitive endogenous RNA mechanism.


Assuntos
Neoplasias Ósseas/patologia , MicroRNAs/genética , Osteossarcoma/patologia , RNA Circular/genética , Proteínas Inibidoras de Apoptose Ligadas ao Cromossomo X/genética , Neoplasias Ósseas/genética , Neoplasias Ósseas/metabolismo , Linhagem Celular Tumoral , Proliferação de Células , Sobrevivência Celular , Regulação Neoplásica da Expressão Gênica , Humanos , Estadiamento de Neoplasias , Osteossarcoma/genética , Osteossarcoma/metabolismo , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo , Proteínas Inibidoras de Apoptose Ligadas ao Cromossomo X/metabolismo , Proteína X Associada a bcl-2/metabolismo
4.
J Orthop Surg Res ; 15(1): 348, 2020 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-32831125

RESUMO

BACKGROUND: We propose a new classification system for chronic symptomatic osteoporotic thoracolumbar fracture (CSOTF) based on fracture morphology. Research on CSOTF has increased in recent years; however, the lack of a standard classification system has resulted in inconvenient communication, research, and treatment. Previous CSOTF classification studies exhibit different symptoms, with none being widely accepted. METHODS: Imaging data of 368 patients with CSOTF treated at our hospital from January 2010 to June 2017 were systematically analyzed to develop a classification system. Imaging examinations included dynamic radiography, computed tomography scans, and magnetic resonance imaging. Ten investigators methodically studied the classification system grading in 40 cases on two occasions, examined 1 month apart. Kappa coefficients (κ) were calculated to determine intraobserver and interobserver reliability. Based on the radiographic characteristics, the patients were divided into 5 types, and different treatments were suggested for each type. Clinical outcome evaluation included using the visual analog score (VAS), the Oswestry disability index (ODI), and the American Spinal Injury Association (ASIA) impairment scale. RESULTS: The new classification system for CSOTF was divided into types I-V according to whether the CSOTF exhibited dynamic instability, spinal stenosis or kyphosis deformity. Intra- and interobserver reliability were excellent for all types (κ = 0.83 and 0.85, respectively). The VAS score and ODI of each type were significantly improved at the final follow-up compared with those before surgery. In all patients with neurological impairment, the ASIA grading after surgery was significantly improved compared with that before surgery (P < 0.001). CONCLUSIONS: The new classification system for CSOTF demonstrated excellent reliability in this initial assessment. The treatment algorithm based on the classification can result in satisfactory improvement of clinical efficacy for the patients of CSOFT.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Fraturas por Osteoporose/classificação , Fraturas por Osteoporose/diagnóstico , Fraturas da Coluna Vertebral/classificação , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Algoritmos , Feminino , Seguimentos , Humanos , Cifose/diagnóstico por imagem , Cifose/etiologia , Cifose/cirurgia , Vértebras Lombares/patologia , Vértebras Lombares/cirurgia , Imageamento por Ressonância Magnética , Masculino , Procedimentos Ortopédicos/métodos , Fraturas por Osteoporose/patologia , Fraturas por Osteoporose/cirurgia , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/patologia , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/patologia , Vértebras Torácicas/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
World Neurosurg ; 134: e243-e248, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31629147

RESUMO

BACKGROUND: Selection of approach for subaxial cervical fracture-dislocation (SCFD) is controversial. The questions of whether a posterior ligamentous structure (PLS) can be functionally healed in patients with SCFD and how long this healing process takes are critical in these patients. METHODS: This study retrospectively enrolled 394 patients with SCFD who underwent anterior decompression, reduction, and fusion between January 2002 and December 2017. The definition of functional healing of PLS was based on evaluations of clinical function and radiographic stability of PLS. RESULTS: Follow-up was available for 354 patients (89.8%). The PLS of 339 cases was functionally healed at the first follow-up interval without any posterior surgical intervention. No hardware failure or progressive cervical kyphosis was observed at further follow-up. At 12 months postoperatively, interbody fusion was satisfactory. However, the other 15 patients experienced nonhealing PLS at 8 weeks postoperatively and developed cervical deformity at further follow-up. Five patients refused revision surgery; the other 10 patients obtained solid fusion after revision surgeries. CONCLUSIONS: Among 354 patients with SCFD and treated by single anterior reduction and fixation, simple PLS injury without any bony instability at the posterior column of the cervical spine can be functionally healed in 95.8% of patients by external fixation for 8 weeks. Whether this finding is applicable to various types of SCFD should be verified in further prospective studies with larger samples.


Assuntos
Vértebras Cervicais/cirurgia , Luxações Articulares/cirurgia , Procedimentos de Cirurgia Plástica/tendências , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/tendências , Adulto , Vértebras Cervicais/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Luxações Articulares/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem
6.
Med Sci Monit ; 25: 2479-2487, 2019 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-30946733

RESUMO

BACKGROUND With the in-depth development of minimally invasive spine surgery in recent years, robot- and computer-assisted technologies have been increasingly used and successfully applied to spinal surgery. MATERIAL AND METHODS We performed a retrospective analysis of 60 patients with grade I or II lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) from January 2017 to December 2017. A robot-assisted surgical system was used in 30 patients for pedicle screw placement. The other 30 patients underwent fluoroscopy-guided percutaneous pedicle screw placement. RESULTS There were 130 screws placed under fluoroscopic guidance, with 26.2% penetration of the pedicle wall. There were 130 screws placed in robotic-assisted surgery, with 6.2% penetration of the pedicle wall. Severe screw deviation (Neo grade III) was identified in 4 screws in the fluoroscopy-guided group, while no severe deviation was noted in the robot-assisted group. In the fluoroscopic group, 15.6% of screws penetrated the superior articular process, and 2.1% screws had severe complications (Babu grade III). However, only 5.1% of screws in the robot-assisted group had severe complications. The mean screw insertion angle was significantly greater in the robot-assisted group than in the fluoroscopy-guided group (23.8±6.1° vs. 18.4±7.2°, P=0.017). CONCLUSIONS Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the following advantages: greater accuracy, lower incidences of screw penetration of the pedicle wall and invasion of the facet joints, and better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis.


Assuntos
Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Espondilolistese/cirurgia , Adulto , Idoso , China , Estudos de Coortes , Feminino , Humanos , Região Lombossacral/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Parafusos Pediculares , Estudos Retrospectivos , Robótica , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 32(11): 1371-1376, 2018 11 15.
Artigo em Chinês | MEDLINE | ID: mdl-30417609

RESUMO

Objective: To explore the clinical application value of the spinal robot-assisted surgical system in mild to moderate lumbar spondylolisthesis and evaluate the accuracy of its implantation. Methods: The clinical data of 56 patients with Meyerding grade Ⅰ or Ⅱ lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) between January 2017 and December 2017 were retrospectively analysed. Among them, 28 cases were preoperatively planned with robotic arm and percutaneous pedicle screw placement according to preoperative planning (group A); the other 28 cases underwent fluoroscopy-guided percutaneous pedicle screw placement (group B). There was no significant difference in gender, age, body mass index, slippage type, Meyerding grade, and surgical segmental distribution between the two groups ( P>0.05). The screw insertion angle was measured by CT, the accuracy of screw implantation was evaluated by Neo's criteria, and the invasion of superior articular process was evaluated by Babu's method. Results: One hundred and twelve screws were implanted in the two groups respectively, 5 screws (4.5%) in group A and 26 screws (23.2%) in group B penetrated the lateral wall of pedicle, and the difference was significant ( χ2=9.157, P=0.002); the accuracy of nail implantation was assessed according to Neo's criteria, the results were 107 screws of degree 0, 3 of degree 1, 2 of degree 2 in group A, and 86 screws of degree 0, 16 of degree 1, 6 of degree 2, 4 of degree 3 in group B, showing significant difference between the two groups ( Z=4.915, P=0.031). In group B, 20 (17.9%) screws penetrated the superior articular process, while in group A, 80 screws were removed from the decompression side, and only 3 (3.8%) screws penetrated the superior articular process. According to Babu's method, the degree of screw penetration into the facet joint was assessed. The results were 77 screws of grade 0, 2 of grade 1, 1 of grade 2 in group A, and 92 screws of grade 0, 13 of grade 1, 4 of grade 2, 3 of grade 3 in group B, showing significant difference between the two groups ( Z=7.814, P=0.029). The screw insertion angles of groups A and B were (23.5±6.6)° and (18.1±7.5)° respectively, showing significant difference ( t=3.100, P=0.003). Conclusion: Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the advantages such as greater accuracy, lower incidence of screw penetration of the pedicle wall and invasion of the facet joints, and has a better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Fusão Vertebral , Espondilolistese , Fluoroscopia , Humanos , Vértebras Lombares , Estudos Retrospectivos , Espondilolistese/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA